iPro2 systemiPro2 DockiPro2 cleaning plugDock USB Cablewall-powered adapterThese are the components of the iPro2 CGM system:• iPro™2 digital recorder

Strany 3

Icon tableDescription IconFollow instructions for useAttention: Read all warnings and precautions ininstructions for use.Stand-by powerCharging/upload

Strany 4

GlossaryArea Under the Curve (AUC) - Indicates the amount in high and low excursions as determined by presetvalues. Excursion data indicates the frequ

Strany 5 - Contents

Study - The period of time that a patient wears a glucose sensor and iPro2. This word also refers to anupload of glucose sensor data from an iPro2 int

Strany 6 - Chapter 4 25 Patient setup

IndexNumerics24 Hour HelpLine 8AaccessingLogbook screen 46accessing CareLink iPro 16accessing patient records 42accuracy, sensor 77activating iPr

Strany 7 - Appendix A 66 Troubleshooting

uploading data 43uploading meter data 45viewing reports 50charging iPro2 63cleaningcleaning plug 63Dock 62iPro2 40, 62USB cable 63wall-powered

Strany 8 - Index 95

guidelines for successful reports 50Iicons 92indications for use 4inserting sensor 31insertion sitesabout 29preparing 30installation of software

Strany 9 - Introduction

performance, sensor 77precautions 5preparing for patient studyabout 26wiping iPro2 with alcohol 27preparing sensor insertion sites 30preparing to

Strany 10

connector pins 73Data Table report 55troubleshooting reference 66Uupgrading Firefox 23upgrading Internet Explorer 23uploadingiPro2 data 43meter

Strany 11

The small end of the Universal Serial Bus (USB) cable connects to the Dock. The other end of thecable connects to a USB port on a computer, so that yo

Strany 12 - User safety

User safetyThis section includes important safety information such as indications, contraindications,warnings, and precautions.Indications for useThis

Strany 13 - Precautions

• An optional occlusive adhesive dressing should be removed if irritation or reaction to the tapedevelops.• The glucose sensor may create special need

Strany 14

Meters supported by CareLink iPro for uploadingData from the following blood glucose meters can be uploaded to CareLink iPro. You will need ameter cab

Strany 15 - Compliance information

Computer system requirementsComputers running CareLink iPro must have the following software installed.• Operating system:-Microsoft® Windows® XP Prof

Strany 16 - Assistance

Interference from wireless devicesCommon wireless consumer devices, such as cellular (mobile) phones or cordless phones, maydisrupt communication duri

Strany 17 - One-time device setup

2One-time device setup!!!!!!activate iPro21Key Notes:• The reset button on the Dock is used to wake up (or activate) the iPro2 because it is shipped i

Strany 18 - One-time iPro2 activation

One-time iPro2 activationThe iPro2 is shipped in a special sleep mode to protect its battery. You need to wake it up byfollowing this one-time procedu

Strany 19

4Place the iPro2 into the Dock.!!The green charging light will start flashing. NOTE: The red warning light may turn on if you do not immediately compl

Strany 20 - Key notes about iPro2

6025420-012_aREF MMT-7745 © 2010 Medtronic MiniMed, Inc. All rights reserved.iPro™ is a trademark of Medtronic MiniMed, Inc.Sen-serter® and CareLink

Strany 21

7Leave the iPro2 on the Dock to continue charging. During charging, the white Dock power lightwill be on, and the green charging light will flash.!8Al

Strany 22

• Never connect an iPro2 to any device other than the Dock, sensor, or cleaning plug. For example,never connect the iPro2 to the charger for the MiniL

Strany 23

3One-time CareLink iPro software andcomputer setupTM32145register cliniccreate Admin user create user accountsset up each computer for uploadingset cl

Strany 24 - Create user accounts

• Usernames must be unique among all CareLink iPro clinics in the system, not just your clinic.• Choose at least two people to be administrative users

Strany 25 - Set clinic report settings

5When prompted, enter the identifying information for your administrative user account (alsoknown as Admin), and click Continue.You will sign in with

Strany 26 - General Report Settings

It is a good idea to give administrative privileges to at least two users. Having two Admin usersmeans that the clinic does not have to rely on only o

Strany 27

If a particular patient has unique needs, you will be able to override these settings later forindividual patients as needed.1 Click the Clinic Settin

Strany 28

Time periods are used to identify which meal to associate with each meal marker. For example, ifthe breakfast time period is set from 6:00 a.m. to 10:

Strany 29

CAUTION: Do not connect the Dock to the computer until specifically told to do so in thisprocedure. If you connect the Dock before the iPro2 Dock driv

Strany 30 - Enabling JavaScript

You should see a small pop-up at the bottom of your screen that says, Medtronic iPro2Dock. This means that the driver for the Dock is successfully ins

Strany 31 - Enabling SSL in FireFox

Contacts:Africa:Medtronic Africa (Pty) Ltd.Tel: +27 (0) 11 677 4800Australia:Medtronic Australasia Pty. Ltd.Tel: 1800 668 670 (product orders)Tel: 180

Strany 32 - Download and print resources

c. Check the box next to Enable Protected Mode.d. Click OK.e. Close Internet Explorer.Required Internet browser settingsOn all computers where you pla

Strany 33 - Patient setup

Secure Sockets Layer (SSL) and encryptionSecure Sockets Layer (SSL) refers to a security protocol designed to protect your Web browsersessions. CareLi

Strany 34 - Preparing for study

Follow the instructions provided by Mozilla to download and install the latest version of Firefox.Download and print resourcesAfter you are finished w

Strany 35

4Patient setupprepare for patientinsert sensorconnect iPro2!32145° to 60°Key Notes:• Use universal precautions when handling the sensor and iPro2.• Do

Strany 36

Preparing for studyBefore the patient arrives in your office, make sure that all the necessary equipment and suppliesare available and ready.!Material

Strany 37 - Where to insert the sensor

Wiping the iPro2 with alcohol before a patient studyThe iPro2 is intended for multiple patient use. Follow this procedure before each patient use.WARN

Strany 38

3Disconnect the cleaning plug from the iPro2 by gently squeezing the arms of the cleaning plug.CAUTION: The o-rings on the cleaning plug have lubrican

Strany 39 - Inserting the sensor

CareLink iPro needs at least one BG meter reading within an expected range every 12 hours.Erroneous BG meter readings may be ignored by CareLink iPro

Strany 40

• Areas with firm skinDo not insert the sensor in:• Frequently used injection or infusion sites.• The 2 inch (5.0 cm) area around the patient's n

Strany 41 - Briefing the patient

NOTE: Do not use sticky skin preparation solutions before inserting the sensor. A stickyintravenous (I.V.) preparation solution may be used after the

Strany 42 - Care and wearing instructions

Schweiz:Medtronic (Schweiz) AGTel: +41 (0)31 868 016024-Stunden-Hotline: 0800 633333Fax Allgemein: +41 (0)318680199Serbia & Montenegro:EpsilonTel:

Strany 43

10 Make sure the sensor is fully inserted. If the sensor is not fully inserted, manually push it intoplace. The plastic sensor base should lay flat on

Strany 44

Briefing the patientThe patient must receive detailed instructions on wearing the sensor and iPro2, studycompliance, meter use and maintaining a log s

Strany 45

3 Make sure that the patient's blood glucose meter has a good battery that will last for the entirelength of the study.4 Check the date and time

Strany 46

Make sure that the patient can return the iPro2 to the clinic well within 10 days of the end of thestudy. After 10 days, if the iPro2 is not connected

Strany 47 - Before you begin

4Push the iPro2 onto the sensor until the sensor's flexible side arms snap into the notches on theiPro2. If the iPro2 is properly connected, and

Strany 48 - Cleaning the iPro2

Important: If the sensor is pulled out by more than a millimeter, the iPro2 will stop collectingdata until the sensor is pushed back in place. When th

Strany 49

5Uploading data to CareLink iPro!12remove iPro2 and sensorupload dataKey Notes:• Always clean and disinfect the iPro2 before connecting it to the Dock

Strany 50 - Opening the patient record

• Do not connect more than one Dock or blood glucose meter to the computer at one time.Before you beginWhen the patient returns after wearing the iPro

Strany 51 - Uploading iPro2 data

3Hold iPro2 as shown, and pinch the flexible side arms of the sensor between your thumb andforefinger. Do not twist the iPro2 relative to the sensor.4

Strany 52

CAUTION: Do not twist the cleaning plug while it is attached to the iPro2. This willdamage the iPro2.CAUTION: The o-rings on the cleaning plug have lu

Strany 53

ContentsChapter 1 1 Introduction2iPro2 system4 User safety4 Indications for use4 Contraindications4 Warnings5 Precautions6 Meters supported by CareLin

Strany 54 - Opening the Logbook

7Disconnect the cleaning plug from the iPro2 by gently squeezing the arms of the cleaning plug.8 Place the iPro2 on a clean, dry, non-shedding cloth a

Strany 55 - Excluding BG meter readings

Uploading iPro2 data1Verify that the iPro2 you are about to upload is for the patient whose record you are viewing inCareLink iPro:a. Find the serial

Strany 56 - Sorting the Logbook entries

You can also connect the Dock to the computer using a USB hub. However, if the white Dockpower light does not turn on, then try using a powered USB hu

Strany 57 - CareLink iPro reports

If you see a message that instructs you to see the User Guide, please look up that message inTroubleshooting reference on page 66.7 Check the green ch

Strany 58

You can also choose to enter BG meter readings manually using the Logbook. For details, seeEntering Patient Log Sheet data on page 46.2 Follow the on-

Strany 59 - About reports

Adding Logbook entriesCareLink iPro calibrates the sensor glucose data using the patient’s BG meter readings that areuploaded or entered manually. If

Strany 60

When you view the patient’s reports, the BG meter readings that you excluded will not beshown, and they will not affect the sensor information in the

Strany 61 - Patient Report Settings

6CareLink iPro reportsviewing and printing reports1Key Notes:• You can modify a patient's Report Settings, such as the glucose target range and m

Strany 62

Viewing and printing patient reportsAfter uploading and entering all of a patient’s study data into CareLink iPro, you have two optionsfor viewing the

Strany 63 - Exporting data to CSV file

About reportsCareLink iPro reports show up to seven calendar days of study data. The reports are created inPDF format, so they can easily be stored el

Strany 64 - CareLink iPro ongoing use

23 Secure Sockets Layer (SSL) and encryption23 Enabling SSL in Internet Explorer23 Enabling SSL in FireFox24 Download and print resourcesChapter 4 25

Strany 65 - User tasks

If the BG meter reading range is less than 100 mg/dL (or 5.6 mmol/L), then an MAD% of 18.0 orless is considered optimal.• # Valid Calibrations: 3 or m

Strany 66 - Modifying clinic information

Area under the curve (AUC)Area under the curve (AUC) information appears in the Excursion Summary on the Daily OverlayReport. AUC provides more insigh

Strany 67 - Administrator tasks

Modifying Patient Report Settings1 Click the Edit link in the Patient Report Settings section of the patient record screen.The patient’s General Repor

Strany 68 - Deleting user accounts

Generating a Data Table reportIf necessary, you can generate a Data Table report (about 15 pages or more). This report lets youview detailed sensor gl

Strany 69 - System maintenance

7CareLink iPro ongoing useuser tasksadministrator tasks21Key Notes:•Click the Resources hyperlink in CareLink iPro to print the newest log sheets and

Strany 70 - Cleaning the Dock

User tasksPrinting more log sheets and other formsYour original iPro2 shipment may have included samples of Patient Log Sheets, ClinicEquipment Logs,

Strany 71

Moving a patient studyIf you accidentally upload an iPro2 study to the wrong patient record in CareLink iPro, you canmove the study to the correct pat

Strany 72 - Storage and organization tips

Administrator tasksIf you are administrative user, you will need to create, modify, or delete CareLink iPro useraccounts for your clinic as new employ

Strany 73

2 Select the user account and click the Open user button. The user account information appears.3 If you want to edit the user account information, suc

Strany 74 - Troubleshooting

8System maintenance!!!cleaning and disinfectingstoring equipment12Key Notes:• Always connect the cleaning plug to the iPro2 before cleaning.• When not

Strany 75

55 Generating a Data Table report55 Exporting data to CSV fileChapter 7 56 CareLink iPro ongoing use57 User tasks57 Printing more log sheets and other

Strany 76

Cleaning the iPro2The iPro2 is intended for multiple patient use. Always clean and disinfect the iPro2 after removingit from a patient. Make sure to c

Strany 77

Components that cannot be cleanedYou cannot clean the following components of the iPro2 system:• Cleaning plugs (discard each cleaning plug after 30 u

Strany 78 - CareLink iPro messages

If your clinic has only one iPro2, you can leave the Dock connected to the computer and connectthe iPro2 to the Dock when not in use. The computer sup

Strany 79

You can organize your other iPro2 supplies in a small drawer organizer, such as the one shownhere. These are some of the items that you will want to k

Strany 80

ATroubleshootingThis appendix contains troubleshooting information for the iPro2 CGM System. Please refer tothese instructions before contacting the 2

Strany 81

Troubleshooting referenceProblem Possible causes What to doThe iPro2 has beenconnected to the Dockwith adequate power fortwo to three hours, but thegr

Strany 82 - Dock lights quick reference

Troubleshooting referenceProblem Possible causes What to doThere are gaps in thesensor data in the reports.A common cause of datagaps is partial senso

Strany 83 - Resetting the iPro2

Troubleshooting referenceProblem Possible causes What to doI connected the iPro2 tothe Dock and all threelights are flashing on andoff repeatedly.!!!!

Strany 84

CareLink iPro messagesCareLink iPro error messagesProblem Possible causes What to doCareLink iPro displayedthis message during theupload process:iPro2

Strany 85 - Sensor performance

CareLink iPro error messagesProblem Possible causes What to doCareLink iPro displayedthis message during theupload process:The iPro2 Recorderbattery i

Strany 86

Glossary 93Index 95iPro2 CGM User Guide Contents viii

Strany 87 - Clarke error grid analysis

CareLink iPro error messagesProblem Possible causes What to doCareLink iPro displayedthis message during theupload process:Transfer failed: Anunrecove

Strany 88 - Reference BG (mg/dL)

Checking the iPro2 connector pinsIf the troubleshooting reference advises you to check the connector pins of the iPro2, use thefollowing image to assi

Strany 89

Dock lights quick referenceDock lights Description What it means!All of the lights are off.The Dock is not plugged into an electrical outlet orcompute

Strany 90 - Percent agreement

Resetting the iPro2CAUTION: This procedure erases all patient data from the iPro2. Do not perform these stepsunless you have already uploaded the last

Strany 91 - Precision

5 Wait for the Dock to show a solid green charging light . This indicates that the data has beencleared, and the iPro2 is fully charged and ready for

Strany 92 - Limitations

BSensor performanceOverviewThe performance of the glucose sensor was assessed using post-hoc analysis1 of a 10-monthrandomized multicenter study2. Sen

Strany 93 - Specifications and notices

Mean absolute relative difference (MARD or MAD%)Adult SubjectsUsing the iPro2 algorithm, the MARD for adult subjects was 10.8% with a standard deviati

Strany 94

MARD (%) by day, pediatric subjects40-400 mg/dL(2.22-22.20mmol/L)40-80 mg/dL(2.22-4.44mmol/L)81-120 mg/dL(4.50-6.66mmol/L)121-240 mg/dL(6.72-13.32mmol

Strany 95

Zone40-400 mg/dL(2.22-22.20mmol/L)40-80 mg/dL(2.22-4.44mmol/L)81-120 mg/dL(4.50-6.66mmol/L)121-240 mg/dL(6.72-13.32mmol/L)241-400 mg/dL(13.38-22.20mmo

Strany 96

Zone40-400 mg/dL(2.22-22.20mmol/L)40-80 mg/dL(2.22-4.44mmol/L)81-120 mg/dL(4.50-6.66mmol/L)121-240 mg/dL(6.72-13.32mmol/L)241-400 mg/dL(13.38-22.20mmo

Strany 97

1IntroductioniPro2 systemuser safetyassistance321Welcome to iPro2 Continuous Glucose Monitoring (CGM)Thank you for your trust in Medtronic products an

Strany 98

Glucose Levels, mg/dL (mmol/L) Performance, mg/dL (mmol/L)121-240 (6.72-13.32)15.6 (0.87)241-400 (13.38-22.20)21.5 (1.20)Pediatric subjectsUsing the i

Strany 99 - Warranty

Sensor Ranges 20% Agreement 30% Agreement 40% Agreement% (n) % (n) % (n)301-350 mg/dL(16.71-19.43 mmol/L)94.9 (187/197) 98.5 (194/197) 99.5 (196/197)3

Strany 100 - Icon table

Precision of the iPro2 system was evaluated in vitro by calibrating sensors in solutions with knownglucose concentrations (measured using a YSI Glucos

Strany 101 - Glossary

CSpecifications and noticesiPro2 system specificationsAtmospheric pressure rangeiPro2: 57.6kPa - 106kPa (16,000 to -1,300 feet [4,880 to -400meters] e

Strany 102

The iPro2 is an internally powered device. The mode of operation is continuous. The iPro2 is notsuitable for use in the presence of a flammable anaest

Strany 103 - Numerics

Guidance and manufacturer's declarationGuidance and Manufacturer's Declaration - Electromagnetic EmissionsThe iPro2 CGM system is intended f

Strany 104

Guidance and Manufacturer's Declaration - Electromagnetic ImmunityThe iPro2 CGM system is intended for use in the electromagnetic environment spe

Strany 105

Guidance and Manufacturer's Declaration - Electromagnetic ImmunityThe iPro2 CGM system is intended for use in the electromagnetic environment spe

Strany 106

Recommended separation distances between portable and mobile RF communications equipment andthe iPro2 CGM systemThis section provides information on t

Strany 107

WarrantyMedtronic Diabetes warrants the iPro2 and Dock to the purchaser of the product against defectsin material and workmanship for a period of one